TPL

The TPL series has a simple line design, which makes it adapt perfectly to urban spaces.

Two sizes that offer a wide range of light packages. The wide variety of optical distributions that it has, provides a uniform and efficient lighting being a quality solution for a wide variety of urban and street applications.

TPL VERSIONS

TPL M

6.185lm – 38.693lm
40 – 270W

TECHNICAL SPECIFICATIONS

Sustainability:

  • Recyclability: 92,48%.
  • Maximum carbon footprint per use: 0,0675 kg/kWh.

CE mark:

  • Yes.

RoHS-compliant:

  • Yes.

Testing standards:

  • LM 79-80 (all measurements at ISO17025 certified laboratory).

Materials:

  • Housing and fork made of aluminium injected cast iron EN AC-44100.
  • Closure tempered glass 5mm thick. It incorporates silicone gasket.
  • Polymethylmethacrylate PMMA optics.
  • Nuts outer and bolts stainless steel (AISI304).

Finish:

  • Gray powder paint RAL 7015 Textured.
  • Marine Finish (1.000h) (Optional).

Watertightness and impact protection grade:

  • IP66.
  • IK09.

Installation and maintenance:

  • As standard, it incorporates cable and connector IP68 watertight prepared for the on-site connection of the luminaire.
  • This way it is not necessary to open and the installation tasks are carried out more quickly and easily.

Weight with equipment:

  • TPL M: 12,2 Kg.

Operating temperature:

  • Ta -40ºC to +50ºC.
    According to luminaire configuration.

Lifespan:

  • L90B10 100,000h a 25ºC.

Wind exposure area:

  • Entre 0,13 y 0,24 m².

Cables:
Built-in cables in all sizes, consult configurator.

Luminaire performance:

  • 6.185lm – 38.693lm
  • 40 – 270W
  • 166 lm/W

LEDs:
Incorporate:

  • 64, 96 and 128 Leds

LED color temperature:

  • 4,000K (Neutral White, nw).
  • 3,000K (Warm White, ww).
  • Optionally amber color temperature.

Index of reproduction chromatic (CRI):

  • CRI>70.
    Other CRI, consult.

ULOR:

  • 0,02% – 0,08%.

Surge protection:

  • Combined discharge voltage (1,2/50) 10 kV
  • Maximum discharge current (8/20) 10 kA
  • Maximum service voltage (L-N) 320 V
  • Maximum service voltage (L/N-GND) 400 V
  • Optional surge protection: 20kA, 20 kV

Electrical class:

  • Class I or Class II.

Harmonic distortion:

  • <10%.

Power factor:

  • > 0,9.

Voltage / Frequency:

  • 220V – 240V / 50Hz – 60Hz.
  • 120V – 277V/ 50Hz – 60Hz.

Equipment:

  • Adjustable LED in header.
  • Dimmable LED Dali Protocol.
  • Dimmable LED 1-10V.
  • Adjustable by line
  • Dual level dimmable LED.
  • Other equipment, consult.

Autonomous regulation:

  • 50% of the 24: 00h at 6: 00h.
  • 60% of the 24: 00h at 6: 00h.
  • 70% of the 24: 00h at 6: 00h.
  • Programming according to client.

CLO regulation:

  • 70% luminous flux throughout the life of the luminaire.
  • 80% luminous flux throughout the life of the luminaire.
  • 90% luminous flux throughout the life of the luminaire.

THE DETAILS MAKE THE DIFERENCE

Closure tempered glass 5mm thick.
It incorporates silicone gasket.

Fork that allow a regulation between -90º and + 90º.

It incorporates cable and connector prepared for the installation in situ of the luminaire and the installation tasks are done much more quickly and easily.

WE SHAPE THE LIGHT

We not only design luminaires, we shape the light and create pleasant environments for people.

TPL_SCE1

SCE1

TPL_SMA1

SMA1

TPL_ACA1

ACA1

TPL_ACE1

ACE1

TPL_ACM1

ACM1

TPL_ACM2

ACM2

TPL_AMA2

AMA2

TPL_AMM1

AMM1

DIMENSION

Applications

Squares and Walks

Car parks

Roundabouts

Loading docks and Tunnels

Do you have a technical question?

Related Products